Measured two sets of output power. + 5V is correct, but + 12V is out of specification. What is the reason?
Measured two sets of output power. + 5V is correct, but + 12V is out of specification. What is the reason?
Ans:
There are multiple sets (more than 2 sets) of output models in Chuanglian products, all of which have Min.Load requirements. Please refer to the specifications before use. When 5V / 4A, 12V / 0A, the output voltage of 12V is too high, about 12.8V has exceeded ± 6% (12.72V) in the specification. At this time, if 12V is added with 0.3A Min. Load according to the specification, then The 12V output voltage can be reduced to approximately 12.3V.